ASTM B840 specification covers the requirements for electrodeposited zinc cobalt alloy coatings on metals.
The following precautionary caveat pertains to the test method portion only, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
There is one coating class, and it is defined as :
There are three grades according to thickness and are defined as follows:
| Minimum Thickness, µm | New ASTM Grade | Old ASTM Grade |
|---|---|---|
| 6 | 6 | 1 |
| 12 | 12 | 2 |
| 18 | 18 | 3 |
| Class | Grade | Type | Base Metal Corrosion | Zinc Alloy Corrosion Product |
|---|---|---|---|---|
| 1 | 12 | A | 240 | 12 |
| 12 | A/E | 340 | 120 | |
| 18 | A | 400 | 12 | |
| 18 | A/E | 500 | 120 | |
| 1 | 6 | B | 240 | 96 |
| 6 | B/E | 340 | 196 | |
| 12 | B | 400 | 96 | |
| 12 | B/E | 500 | 196 | |
| 18 | B | 500 | 96 | |
| 18 | B/E | 600 | 196 | |
| 1 | 6 | C | 240 | 96 |
| 6 | C/E | 340 | 196 | |
| 12 | C | 400 | 96 | |
| 12 | C/E | 500 | 196 | |
| 18 | C | 500 | 96 | |
| 18 | C/E | 600 | 196 | |
| 1 | 6 | D | 240 | 96 |
| 6 | D/E | 340 | 120 | |
| 12 | D | 400 | 96 | |
| 12 | D/E | 500 | 120 | |
| 18 | D | 500 | 96 | |
| 18 | D/E | 600 | 120 |