ISO 3506-1 Specification

Fasteners, Boltings, Stud Bolts, Screws

Scope

High-Quality ISO 3506-1 Stainless Steel Fasteners – Available at Adfast Component LTD

Adfast Component LTD offers premium-quality bolts, screws, and stud bolts conforming to ISO 3506-1 standards. These corrosion-resistant stainless steel fasteners are designed for both coarse and fine pitch threads, ensuring superior mechanical and physical properties. Suitable for ambient temperatures between 10°C to 35°C, they perform efficiently in extreme conditions ranging from -196°C to +300°C.

Our ISO 3506-1 certified fasteners include austenitic, martensitic, ferritic, and duplex (austenitic-ferritic) steel grades, making them ideal for critical industrial applications. Available in sizes from M1.6 to M39, these fasteners guarantee durability and reliability for various engineering and construction needs. Choose Adfast Component LTD for trusted, high-performance fastening solutions!

Designation

Stainless Steel Grades
A1 to A5 & A8 for Austenitic
C1, C3 & C4 for Martensitic
F1 for Ferritic
D2, D4, D6 & D8 for duplex (austenitic-ferritic)
added by a digit which specifies the range of chemical compositions within this stainless steel group

Property Classes
50 for 500 Mpa Tensile Min
70 for 700 Mpa Tensile Min
80 for 800 Mpa Tensile Min
100 for 100 Mpa Tensile Min

Common Designations

Chemical Composition

Mechanical properties

Stainless steel gradeProperty classTensile strength a Rmf min. MPaStress at 0,2 % non-proportional elongation b Rpf mm. MPaElongation after fracture A min. mm
AusteniticA1 A2 A3505002100,6d
707004500,4d
808006000,3d
A4 A5505002100,6d
707004500,4d
808006000,3d
10010008000,2d
A8707004500,4d
808006000,3d
10010008000,2d
DuplexD2  D4 D6 D8707004500,4d
808006000,3d
10010008000,2d
  • a Minimum ultimate tensile loads (Fmf) are specified in Table 4 for coarse pitch thread, and in Table 6 for fine pitch thread.
  • b Minimum loads at Rpf (Fpf) are specified in Table 5 for coarse pitch thread, and in Table 7 for fine pitch thread.
Stainless steel gradeProperty classTensile strength a Rmr min. MPaStress at 0,2 % non-proportional elongation b Rpr mm. MPaElongation after fracture A min. mmHardness min. to max.
HVHRCHBW
MartensiticC1505002500,2d155 to 220147 to 209
707004100,2d220 to 33020 to 34209 to 314
110 c11008200,2d350 to 44036 to 45
C3808006400,2d240 to 34021 to 35228 to 323
C4505002500,2d155 to 220147 to 209
707004100,2d220 to 33020 to 34209 to 314
FerriticF1d454502500,2d135 to 220128 to 209
606004100,2d180 to 285171 to 271
  • a Minimum ultimate tensile loads (Fmf) are specified in Table 4 for coarse pitch thread, and in Table 6 for fine pitch thread.
  • b Minimum loads at Rpf (Fpf) are specified in Table 5 for coarse pitch thread, and in Table 7 for fine pitch thread.
  • c Hardened and tempered at a minimum tempering temperature of 275 °C.
  • d Only for nominal thread diameters d ≤ 24 mm.
Thread dNominal stress area As,nom mm 2Minimum ultimate tensile  load, Fmf a N
Austenitic and duplex steelsMartensitic steelsFerritic steels
50 b70801005070801104560
M35,032520353040305040252035304030554022703020
M3,56,783390475054306780339047505430746030504070
M48,784390615070308780439061507030966039605270
M514,271009930113501419071009930113501561063908510
M620,11007014090161002013010070140901610022140906012080
M728,914430202102309028860144302021023090317501299017320
M836,618310256302929036610183102563029290402701648021970
M1058,029000406004640057990290004060046400637902610034800
M1284,342140589906742084270421405899067420927003792050560
M141155772080810923601155005772080810923601270005195069270
M1615778340109700125400156700783401097001254001724007051094010
M18192962401348001540001925009624013480015400021180086620115500
M20245122400171400195900244800122400171400195900269300110200146900
M22303151700212400242800303400151700212400242800333800136600182100
M24353176300246800282100352600176300246800282100387800158700211600
M27459229800321600367600459500229800321600367600505400
M30561280300392500448500560600280300392500448500616700
M33694346800485500554900693600346800485500554900763000
M36817408400571800653400816800408400571800653400898400
M399764879006831007807009758004879006831007807001073400
  • a Fmf values have been calculated from the exact figures of As,nom as specified in 9.1.5 and rounded to the next upper 10 N up to 100 000 N, and to the next 100 N above.
  • b Property class 50 refers to the austenitic grades A1 to A5 only.
Thread dNominal stress area As,nom mm2Minimum load at 0,2 % non-proportional  elongation, Fpf a N
Austenitic and duplex steelsMartensitic steelsFerritic steels
50 b70801005070801104560
M35,031060227030204030126020703220413012602070
M3,56,781430305040705430170027804340556017002780
M48,781850396052707030220036005620720022003600
M514,2298063908510113503550582090801163035505820
M620,142309060120801610050408260128801651050408260
M728,960701299017320230907220118401848023670722011840
M836,676901648021970292909160150102343030020916015010
M1058,012180261003480046400145002378037120475601450023780
M1284,317700379205056067420210703455053940691002107034550
M1411524250519506927092360288604734073890946702886047340
M1615732910705109401012540039170642401003001285003917064240
M18192404208662011550015400048120789201232001579004812078920
M20245514101102001469001959006120010040015670020080061200100400
M22303637201366001821002428007585012440019420024880075850124400
M24353740301587002116002821008813014460022570028910088130144600
M2745996480206800275700367600114900188400294100376800
M30561117800252300336400448500140200229900358800459700
M33694145700312100416200554900173400284400443900568800
M36817171600367600490100653400204200334900522800669800
M39976205000439100585500780700244000400100624500800200
  • a Fpf values have been calculated from the exact figures of As,nom as specified in 9.1.5 and rounded to the next upper 10 N up to 100 000 N, and to the next 100 N above.
  • b Property class 50 refers to the austenitic grades A1 to A5 only
Thread dxPNominal stress area As,nom mm2Minimum ultimate tensile load, Fmr a N
Austenitic and duplex steelsMartensitic steelsFerritic steels
50 b70801005070801104560
M8x139,219590274203134039170195902742031340430901763023510
M10x1,2561,230600428404896061200306004284048960673202754036720
M10x164,532250451505160064500322504515051600709502903038700
M12x1,588,144070616907051088130440706169070510969403966052880
M12x1,2592,1460406446073660920804604064460736601013004144055250
M14x1,51256228087190996401246006228087190996401371005605074730
M16x1,5167836301171001338001673008363011710013380018400075270100400
M18x1,521610820015140017300021630010820015140017300023790097310129800
M20x2258129000180600206400258000129000180600206400283800116100154800
M20x1,5272135800190100217300271600135800190100217300298700122200163000
M22x1,5333166600233200266500333100166600233200266500366400149900199900
M24x2384192300269100307600384500192300269100307600422900173000230700
M27x2496247900347100396600495800247900347100396600545400
M30x2621310700434900497000621300310700434900497000683400
M33x2761380400532600608700760800380400532600608700836900
M36x3865432500605500692000865000432500605500692000951500
M39x3103051420071990082280010284005142007199008228001131300
  • a Fmf have been calculated from the exact figures of As,nom as specified in 9.1.5 and rounded to the next upper 10 N up to 100 000 N, and to the next 100 N above.
  • b Property class 50 refers to the austenitic grades A1 to A5 only.
Thread d xPNominal stress area As,nom mm2Minimum ultimate tensile load, Fmr a N
Austenitic and duplex steelsMartensitic steelsFerritic steels
50 b70801005070801104560
M8x139,282301763023510313409800160602507032120980016060
M10x1,2561,212860275403672048960153002510039170501901530025100
M10x164,513550290303870051600161302645041280528901613026450
M12x1,588,118510396605288070510220403614056410722702204036140
M12x1,2592,119340414405525073660230203775058930755002302037750
M14x1,5125261605605074730996403114051070797101022003114051070
M16x1,5167351307527010040013380041820685801071001372004182068580
M18x1,5216454109731012980017300054060886601384001774005406088660
M20x2258541801161001548002064005418011610015480021160054180116100
M20x1,5272570201222001630002173006788011140017380022270067880111400
M22x1,5333699501499001999002665008327013660021320027320083270136600
M24x2384807301730002307003076009611015770024610031530096110157700
M27x2496104200223100297500396600124000203300317300406600
M30x2621130500279600372800497000155400254700397600509400
M33x2761159800342400456500608700190200312000487000623900
M36x3865181700389300519000692000216300354700553600709300
M39x31030216000462800617100822800257100421700658200843300
  • a Fpf have been calculated from the exact figures of As,nom as specified in 9.1.5 and rounded to the next upper 10 N up to 100 000 N, and to the next 100 N above.
  • b Property class 50 refers to the austenitic grades A1 to A5 only.
Thread dMinimum breaking torque a MB Nm
Property class
507080
Ml,60,150,20,24
M20,30,40,48
M2,50,60,90,96
M31,11,618
M42,73,84,3
M55,57,88,8
M69,31315
M8233237
M10466574
M1280110130
M16210290330
  • a The drive and/or recess of the fastener are not always able to apply the minimum breaking torque specified in this table; this shall not be the cause for rejection.
tainless steel gradeProperty and related test method
Minimum tensile strength RmrStress at 0,2 % non-proportional elongation RpfElongation after fracture AMinimum breaking torque M BHardness
Tensile test 9.1Wedge tensile test 9.4Tensile test 9.1Tensile test 9.1Torsional test 9.5Hardness test 9.6
Al  A2 A3 A4  A5  A8d ≥ 3 mm I ≥ 2,Sd b ≥ 2dNot relevantd ≥ 3 mm I ≥ 2,Sd b ≥ 2dd ≥ 3 mm I ≥ 2,Sd b ≥ 2 dFor all lengths when d < 3 mm; only for lengths I < 2,Sd when d ≥ 3 mm b ≥ ld + 2 P No value available for property  class 100 or for fine pitch  threadNot applicable
C1  C3  C4d ≥ 3 mm I ≥ 2,Sd b ≥ 2dd ≥ 3 mm I ≥ 2,Sd b ≥ 2dd ≥ 3 mm I ≥ 2,Sd b ≥ 2dd ≥ 3 mm I ≥ 2,Sd b ≥ 2dNo value availableApplicable
F1d ≥ 3 mm I ≥ 2,Sd b ≥ 2dNot relevantd ≥ 3 mm I ≥ 2,Sd b ≥ 2dd ≥ 3 mm I ≥ 2,Sd b ≥ 2dNo value availableApplicable
D2 D4 D6  D8d ≥ 3 mm I ≥ 2,Sd b ≥ 2dNot relevantd ≥ 3 mm I ≥ 2,Sd b ≥ 2dd ≥ 3 mm I ≥ 2,Sd b ≥ 2dNo value availableNot applicable
Notesa ,bb,ca,ba ,bc
  • a For fully threaded studs, total length lt ≥ 3,5d.
  • b For l < 2,5d (or lt < 3,5d for fully threaded studs), testing and test conditions shall be agreed between the purchaser and the manufacturer.
  • c Only for bolts and screws (not for studs)
Stainless steel gradeProperty and related test method
Minimum tensile strength RmrStress at 0,2 % non-proportional elongation RpfElongation after fracture AMinimum tensile  load FmrHardness
Tensile test 9.1, 9.3Tensile test 9.1Tensile test 9.1Tensile test 9.2Hardness test 9.6
Al A2 A3 A4 A5 A8d ≥ 3 mm for all lengths, when b ≥ 3d ad ≥ 3 mm for all  lengthsNot applicable
C1 C3 C4Applicable
F1Applicable
D2 D4 D6 D8Not applicable
  • a A nominal thread length of at least 3d is necessary to carry out the tensile test in accordance with Figure 2 d), i.e. 1d of free threaded length and additional 1d of engaged threads at both ends.
Nominal thread diameter d mmBolts and screws with unthreaded shank length l s ≥ 2dScrews threaded to the head Bolts and screws with u nthreaded shank length l s < 2d
α ± 30′
3 ≤ d ≤ 2010°
20 < d ≤ 39

Marking

Heat Treatment