asme-b18-6-3-slotted-oval-countersunk-head-machine-screws

Dimensions of ASME B18.6.3 Slotted Oval Countersunk Head Machine Screws

Nominal Size or Basic Screw DiameterLength, LHead Diameter, AHead Side Height, HHead Crown Height, CTotal Head Height, OSlot Width, JSlot Depth, TProtrusion Above Gaging Diameter, FGaging Diameter, G
MaxMinMaxMinMaxMinMaxMin
000.0870.0800.0280.0140.0420.0170.0100.0230.016Note 6Note 6Note 6
01/80.1120.0960.0350.0210.0560.0230.0160.0300.0250.0470.0310.078
11/80.1370.1200.0430.0250.0680.0260.0190.0380.0310.0530.0350.101
21/80.1620.1440.0510.0290.0800.0310.0230.0450.0370.0580.0390.124
31/80.1870.1670.0590.0330.0920.0350.0270.0520.0430.0640.0440.148
43/160.2120.1910.0670.0370.1040.0390.0310.0590.0490.0690.0480.172
53/160.2370.2150.0750.0410.1160.0430.0350.0670.0550.0750.0530.196
63/160.2620.2380.0830.0450.1280.0480.0390.0740.0600.0800.0570.220
81/40.3120.2850.1000.0520.1520.0540.0450.0880.0720.0910.0660.267
105/160.3620.3330.1160.0600.1760.0600.0500.1030.0840.1020.0750.313
123/80.4120.3800.1320.0680.2000.0670.0560.1170.0960.1130.0840.362
1/47/160.4770.4420.1530.0790.2320.0750.0640.1360.1120.1290.0950.424
5/161/20.5970.5560.1910.0990.2900.0840.0720.1710.1410.1550.1170.539
3/89/160.7170.6700.2300.1170.3470.0940.0810.2060.1700.1820.1390.653
7/165/80.7600.7150.2230.1220.3450.0940.0810.2100.1740.1950.1500.690
1/23/40.8150.7650.2230.1310.3540.1060.0910.2160.1760.2120.1630.739
9/160.9320.8780.2600.1500.4100.1180.1020.2500.2070.2390.1840.851
5/81.0500.9900.2980.1690.4670.1330.1160.2850.2350.2660.2060.962
3/41.2851.2150.3720.2060.5780.1490.1310.3530.2930.3180.2401.186

Notes :

  • Where specifying nominal size in decimals, zeros preceding the decimals and in the fourth decimal place shall be omitted.
  • Screws of these length and shorter shall have undercut heads.
  • Tabulated values determined from formula for maximum H in Appendix A.
  • Tabulated values determined from formula for maximum O in Appendix A.
  • No tolerance for gaging diameter is given. If the gaging diameter of the gage used differs from tabulated value, the protrusion will be affected accordingly and the proper protusion values must be recalculated using the formulas.
  • Not practical to gage.